Advanced ultrasonic pulse velocity and pulse echo testing

To assess structural integrity and localize defects in concrete and rock

Structural defects cause serious damages and collapses. Ultrasonic testing provides information on the strength and uniformity of concrete, rock, composites, ceramics, wood, epoxy, refractory materials and can be used to detect and localize voids, pipes, cracks and defects. The ultrasonic pulse echo (UPE) technology extends ultrasonic pulse velocity (UPV) applications to objects where access is restricted to a single side. Proceq offers the most versatile range of ultrasonic testing instruments. 

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Description
Description

The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set. 

Description

The Pundit 200 is a best-in-class UPV test instrument with an extended range of measurement modes. Rugged touchscreen with intuitive user interface for best possible measuring and analysis of the measured data. 

Description

The Pundit 200 Pulse Echo extends the ultrasonic application to objects where access is restricted to a single side. Major applications are slab thickness measurments and the location of voids and delaminations. Rugged touchscreen with intuitive user interface. 

Your Benefits
Your Benefits
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements

Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements

Open interface, can be integrated into LabView

Open interface, can be integrated into LabView

Pundit Lab+ removes the need for external amplification when used with exponential transducers

Pundit Lab+ removes the need for external amplification when used with exponential transducers

Your Benefits
Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement

Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement

Automatic surface velocity calculation according to standards

Automatic surface velocity calculation according to standards

Same instrument can be used with pulse echo transducers

Same instrument can be used with pulse echo transducers

Your Benefits
B-Scan is constructed directly on the instrument as the scan is carried out

B-Scan is constructed directly on the instrument as the scan is carried out

Can be upgraded to Multi Channel

Can be upgraded to Multi Channel

Same instrument can be used with classic pulse velocity transducers

Same instrument can be used with classic pulse velocity transducers

Measuring Range
Measuring Range

Up to 15 m depending on concrete quality

Measuring Range

Up to 15 m depending on concrete quality

Measuring Range

Up to 1 m depending on concrete quality

Bandwidth
Bandwidth

20 to 500 kHz

Bandwidth

20 to 500 kHz

Bandwidth

20 to 500 kHz

Technology
Technology

Ultrasonic pulse velocity

Technology

Ultrasonic pulse velocity

Technology

Single channel ultrasonic pulse echo

Measuring Resolution
Measuring Resolution

0.1 us

Measuring Resolution

0.1 us

Measuring Resolution

0.1 us

Pulse Voltage UPV
Pulse Voltage UPV

125 to 500 V

Pulse Voltage UPV

100 to 450 Vpp

Pulse Voltage UPV
Pulse Voltage UPE
Pulse Voltage UPE
Pulse Voltage UPE
Pulse Voltage UPE

100 to 400 Vpp

Receiver Gain
Receiver Gain

1x, 10x, 100x, AUTO, Pundit Lab+ up to 1000x

Receiver Gain

1 to 10’000x (0 to 80 dB)

Receiver Gain

1 to 10’000x (0 to 80 dB)

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Quality assessment and uniformity
Quality assessment and uniformity
Quality assessment and uniformity
Quality assessment and uniformity
Compressive strength estimation
Compressive strength estimation
Pundit Lab+ only
Compressive strength estimation
Compressive strength estimation
SONREB
SONREB
Pundit Lab+ only
SONREB
SONREB
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Curing status evaluation
Curing status evaluation
Curing status evaluation
Curing status evaluation
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Crack depth estimation
Crack depth estimation
Crack depth estimation
Crack depth estimation
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Construction
Construction
Engineering
Engineering
Conservation
Conservation
Ready mix
Ready mix
Academics, research and education
Academics, research and education
Inspection
Inspection
Geology
Geology
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Instrument Firmware
Instrument Firmware
  • Open interface
  • Integrated amplifier gain stage (Pundit Lab+ only)
  • Real time stamp (Pundit Lab+ only)
Instrument Firmware
  • Zoom and scroll for precise A-Scan inspection
  • On board storage and review of waveforms
  • Settings directly accessible on measuring screen
  • Dual cursor for manual A-Scan evaluation
  • Separate cursor to measure signal amplitude
  • Automatic and manual triggering and user adjustable trigger threshold
  • A-Scan update rate up to 25 Hz
Instrument Firmware
  • Gate function
  • Raw data export
  • Settings directly accessible on measuring screen
  • Advanced echo tracking technology helps identifying the main echo
  • Automatic estimation of the Pulse Velocity
PC Software
PC Software

Pundit Link unlocks the full Pundit Lab+ capabilities

PC Software

PL-Link for analysis and export data to third party applications

PC Software

PL-Link for analysis and export data to third party applications

Display
Display

79 x 21 mm passive matrix OLED

Display

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Display

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Memory
Memory

> 500 measured values

Memory

Internal 8 GB flash memory

Memory

Internal 8 GB flash memory

Connections
Connections

USB connection to PC

Connections

USB host / device and Ethernet

Connections

USB host / device and Ethernet

Measurement Modes
Measurement Modes
  • Pulse velocity
  • Surface velocity
  • Data logging
  • E-modulus
  • Compressive strength correlation (Pundit Lab+ only)
  • Crack depth
Measurement Modes
  • Pulse velocity
  • Surface velocity
  • Data logging
  • E-modulus
  • Compressive strength correlation
  • Crack depth
  • Line Scan
  • Area Scan
Measurement Modes
  • Pulse velocity
  • Area Scan
  • A-Scan
  • B-Scan
  • Distance
Transducers
Transducers
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Transducers
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Transducers
  • Dry-contact Pundit Pulse Echo transducer with control buttons, optical feedback, center marker and rulers for easy B-Scan measurements
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Standards
Standards
  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21
Standards
  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21
Standards
Guidelines
Guidelines
Guidelines
Guidelines
  • RI-ZFP-TU
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Measurement Accessories
Measurement Accessories
  • 2 S-Wave Transducers, 250 kHz, incl. couplant
  • 2 Exponential transducer 54 kHz, including calibration rod
  • 2 Transducers 150 kHz
Measurement Accessories
  • Pundit Pulse Echo Transducer, incl. cable, contact tester and documentation
  • 2 S-Wave Transducers, 250 kHz, incl. couplant
  • 2 Exponential transducer 54 kHz, including calibration rod
Measurement Accessories
  • Pundit PL-200PE UPV Kit
  • 2 S-Wave Transducers, 250 kHz, incl. couplant
  • 2 Exponential transducer 54 kHz, including calibration rod
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Product videos