Pull Off Tester - Dyna
Pull Off Tester - Dyna

A pull off tester is indispensable for the diagnosis of building structure damages as well as for checking complete renovation work. The Dyna pull off tester is used to determine the surface strength of concrete and other materials testing it directly on the component allowing the use of any measuring point. Additionally, the Dyna pull off tester can be used for the measuring of the adhesive strength of applied coatings such as plastic coatings, concrete coats, and mortars and plasters. This mobile pull off tester allows testing on any point of a structure without having to install test devices prior to the casting of concrete.

Features
  • Dyna pull off tester has an integrated digital manometer (with metric and imperial units)
  • The pull off tester Dyna is mobile, lightweight and precise
  • Constant jerk-free load increase
  • An optional electrical drive unit is available with the pull off tester
Application
  • The pull off tester measures the adhesive strength of applied coatings e.g. plastic or concrete coatings, mortars, plasters, bituminous coats
  • Determining the surface strength of concrete and other materials
  • The pull off tester is ideal for the evaluation of tensile strength in concrete renovation
Standardization

The following standards can be applied to the pull off tester:

  • ISO 4624
  • EN 1015-12
  • EN 1348
  • BS 1881 Part 207
  • ASTM C 1583
  • ASTM D 4541
  • ACI 503-30
  • DIN 1048 Part 2
Product Variations
  • Pull off tester Dyna Z series with integrated digital manometer
  • Pull off tester Dyna ZE series with pressure sensor and electronic display device  which allows the easy data-transfer to a PC or printer
  • Optional electric drive EDm available with the pull off tester
  • Pull off tester Dyna Estrich is specially designed to measure the adhesive strength of floor coatings
Technical Data
Pull off tester Dyna Z and Dyna ZE
Dyna ZDyna ZE
Pull off tester
Z16
Pull off tester
Z6
Pull off tester
Z16
Pull off tester
Z6
Tensile force16 kN
(3'600 lbf)
6 kN
(1'350 lbf)
16 kN
(3'600 lbf)
6 kN
(1'350 lbf)
Resolution0.01 N/mm2
Accuracy< 2 % full range < 2 % full range
Permissible stroke3.5 mm4.0 mm3.5 mm4.0 mm
Weight3.5 kg (7 lbs; 11 oz)
Batterytype CR 2430 for manometer
for 150 h operation
See below for display unit
Operating temperature0 ° to +60 °C (32 °F to 140 °F)
Storage temperature-10 ° to +60 °C (14 °F to 140 °F)
Total weight6 kg (13 lbs; 3 oz)7.8 kg (17 lbs; 3 oz)
Pull off tester Dyna ZE - Dynameter display device
Memorynon-volatile memory for 1’000 measured values
Displaygraphic LCD display 128 x 128 pixel with backlight
Data outputRS 232 interface or with adapter to USB
Softwareintegrated software for the transmission of measured values to a printer or PC
Batterysix LR6 (AA), 1.5 V (60 h operation)
Weight1.8 kg (4 lbs)

Warranty

  • Standard 2-year limited warranty on electronic parts of the pull off tester
  • Optional extended warranty periods up to 3 additional years

For more information on Dyna pull off tester contact us.