Please select a region to display the responsible contact person.
The Equostat is a practical complement to Proceq’s portable rebound hardness testers as it resolves most limitations associated with the dynamic testing method.
While rebound hardness testers are not suitable to measure very light parts of certain geometries, the portable Equostat is well-suited for testing light, thin-walled or tubular parts.
The Equostat measures according to the Rockwell principle where the penetration depths under a defined preload are measured before and after application of a larger force.
These low-load penetration depth measurements are accurate, rapid and reproducible.
The difference between the before and after penetration depths reflects the plastic deformation and, therefore, the hardness.

Proceq offers accessories such as a hand activated clamp (incl. in the “clamp unit”), a free-hand flat foot (incl. in the “R-H unit”) for testing on large surfaces, support adapters for round parts, and a bench press to address individual testing requirements.
Optional extended warranty periods up to 3 additional years
| Equostat unit incl. R5 probe | |
| Testing method | static low-load Rockwell |
| Available probes | R5 (also Leeb rebound probes can be used) |
| Test load | preload 10N, total load 50N |
| Conical test tip | diamond, point angle 80° |
| Min. radius of surface curvature | 1.5 mm (0.06 in.) |
| Penetration depth | soft materials approx. 80 μm (0.003 in.) hard materials approx. 15 μm (0.0006 in.) |
| Resolution | 0.1 HRZ; 1 HV; 1 HB; 0.1 HRB; 0.1 HRC; 0.1 HR15N; 1 MPa (1 N/mm2) |
| Accuracy | ± 1.5 HRZ (± 2.0 HRC) throughout the entire measuring range |
| Equotip 2 indicating device | |
| Dimensions | 175 x 180 x 80 mm (6.9 x 7.1 x 3.15 in.) |
| Weight | 750 g (incl. batteries) |
| Material | shock resistant ABS plastic |
| Display | large LCD |
| Internal data storage | ~ 5’000 values |
| Communication | RS232 C |
| PC application | Equolink 2 software included |
| Battery type | standard size "AA" cells (LR6) for about 65 h operation |
| Operating temperature | 0 - 50 °C (32 - 122 °F) |