Corrosion potential, concrete resistivity and permeability testers
Service life and durability assessment of reinforced concrete structures
The construction industry is rapidly moving towards performance based specifications for concrete durability of new structures; at the same time the assessing of service life of actual reinforced concrete elements is being a subject of increasing concern in the industry. Half-cell potential, concrete resistivity and concrete cover air permeability are the main and most widely accepted indicators of likelihood of corrosion and estimated durability of a concrete structure.
Proceq’s Profometer Corrosion, Resipod and Torrent instruments are designed and manufactured to assess the durability of concrete structures by measuring corrosion potential, concrete resistivity and permeability.
![]() Profometer Corrosion |
![]() Resipod |
![]() Torrent |
Profometer Corrosion |
Resipod |
Torrent |
---|
Description |
Description
Advanced half-cell measuring instrument for on-site mapping of the corrosion potential. Dedicated software for assisted measurements with rod and wheel electrodes. Statistical software for immediate data interpretation. |
Description
A complete solution for measuring the electrical resistivity of concrete both in the laboratory under controlled conditions and on site. Standard fixed spacing surface Wenner probe with variable spacing and bulk resistivity accessories. |
Description
Air permeability tester for the on-site assessment of the concrete quality by mean of the unique two-chamber vacuum cell principle. |
Your Benefits |
Your Benefits
![]() High productivity with unique wheel electrodes ![]() Advanced processing and reporting tools ![]() Easy upgradable with cover meter functionality for combined testing |
Your Benefits
![]() All-in-one solution for concrete electrical resistivity testing ![]() Equally reliable, accurate and standardized but faster than laboratory RCP testing ![]() Rugged water-proof construction |
Your Benefits
![]() Rapid assessment of air permeability ![]() Totally non-destructive measuring principle ![]() Correlates well with traditional durability related tests |
Available Upgrades |
Available Upgrades
To Profometer 6 Cover Meters |
Available Upgrades
|
Available Upgrades
|
Measured Quantity |
Measured Quantity
Corrosion potential [mV] |
Measured Quantity
Electrical resistivity [kΩcm] |
Measured Quantity
Permeability coefficient kT [10-16m2] |
Accuracy |
Accuracy
±1 mV |
Accuracy
From ±0.2 to ±2 kΩcm (depending on resistivity range) |
Accuracy
|
Profometer Corrosion |
Resipod |
Torrent |
---|
On-site assessment of corrosion likelihood |
On-site assessment of corrosion likelihood
|
On-site assessment of corrosion likelihood
|
On-site assessment of corrosion likelihood
|
Corrosion rate estimation |
Corrosion rate estimation
|
Corrosion rate estimation
|
Corrosion rate estimation
|
Concrete resistance to aggressive agents |
Concrete resistance to aggressive agents
|
Concrete resistance to aggressive agents
|
Concrete resistance to aggressive agents
|
Concrete homogeneity |
Concrete homogeneity
|
Concrete homogeneity
|
Concrete homogeneity
|
Curing conditions |
Curing conditions
|
Curing conditions
|
Curing conditions
|
Effectiveness of coatings |
Effectiveness of coatings
|
Effectiveness of coatings
|
Effectiveness of coatings
|
Checking fiber distribution in a steel fiber reinforced concrete |
Checking fiber distribution in a steel fiber reinforced concrete
|
Checking fiber distribution in a steel fiber reinforced concrete
|
Checking fiber distribution in a steel fiber reinforced concrete
|
Assessment of fire damaged structures |
Assessment of fire damaged structures
|
Assessment of fire damaged structures
|
Assessment of fire damaged structures
|
Additional Applications |
Additional Applications
|
Additional Applications
|
Additional Applications
|
Profometer Corrosion |
Resipod |
Torrent |
---|
Instrument Firmware |
Instrument Firmware
|
Instrument Firmware
|
Instrument Firmware
Data transfer capabilities to third party software |
PC Software |
PC Software
Profometer Link Reporting software for data analysis, combined data evaluation and reporting on any third party software |
PC Software
ResipodLink to view and manipulate the data on a connected PC. It also allows a variable contact spacing to be set. |
PC Software
|
Display |
Display
7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor |
Display
Pixel graphic LCD |
Display
128 x 128 graphic LCD |
Memory |
Memory
Internal 8 GB flash memory |
Memory
500 measured values |
Memory
200 measured values |
Connections |
Connections
USB host / device and Ethernet |
Connections
USB type B |
Connections
RS 232 or optional adapter to USB |
Measuring Range |
Measuring Range
-999 to +999 mV |
Measuring Range
1 to approx. 1000 kΩcm (depending on probe spacing) |
Measuring Range
-10 °C to +60 °C |
Probes / Electrodes |
Probes / Electrodes
In addition to the basic rod electrode, the use of Proceq’s unique one and four wheel electrodes enable the highest on site productivity on large areas |
Probes / Electrodes
In addition to the standard Wenner probe with spacing of 50 mm or 38 mm (1.5"), additional variable spacing probe and bulk resistivity accessories available |
Probes / Electrodes
|
Profometer Corrosion |
Resipod |
Torrent |
---|
Standards |
Standards
|
Standards
|
Standards
|
Profometer Corrosion |
Resipod |
Torrent |
---|
Measurement Accessories |
Measurement Accessories
|
Measurement Accessories
|
Measurement Accessories
Adapter RS 232 / USB (390 00 540) |
Profometer Corrosion |
Resipod |
Torrent |
---|
Documents |
Documents
|
Documents
|
Documents
|
Software |
Software
|
Software
|
Software
|
Media |
Media
|
Media
|
Media
|
Profometer Corrosion |
Resipod |
Torrent |
---|
Request an offer | Request an offer | Request an offer |