En
Pundit ultrasonic instruments

Pundit ultrasonic pulse velocity and pulse echo tomography

Pundit ultrasonic instruments

Assessment of structural integrity and localization of defects and voids in concrete and rock through ultrasonic testing

Structural defects cause serious damages and collapses. Ultrasonic testing provides information on the strength and uniformity of concrete, rock, composites, ceramics, wood, epoxy, refractory materials and can be used to detect and localize voids, pipes, cracks and defects. The ultrasonic pulse echo (UPE) technology extends ultrasonic pulse velocity (UPV) applications to objects where access is restricted to a single side. Proceq Pundit offers the most versatile range of ultrasonic testing instruments.

 

Related category:  Pundit Vision​​​​​​​   Roll hardness testers   Schmidt rebound hammers

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Description
Description

The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set. 

Description

The Pundit 200 is a best-in-class UPV test instrument with an extended range of measurement modes. Rugged touchscreen with intuitive user interface for best possible measuring and analysis of the measured data. 

Description

The Pundit 200 Pulse Echo extends the ultrasonic application to objects where access is restricted to a single side. Major applications are slab thickness measurments and the location of voids and delaminations. Rugged touchscreen with intuitive user interface. NewPundit® Dry-Point Shear Wave Transducer

Description

The Pundit 250 Array is a modular phased array pulse echo instrument incorporating dry-point contact transducers. It features unique real time B-Scans as well as on-site C-scans, P-scans and Volume scans.

Description

Pundit PD8000, the wireless inspection solution with multi-channel ultrasonic pulse echo technology, brings on-site structural concrete assessment and imaging to the next level when it comes to pragmatism and productivity. 

Your Benefits
Your Benefits
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements

Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements

Open interface, can be integrated into LabView

Open interface, can be integrated into LabView

Pundit Lab+ removes the need for external amplification when used with exponential transducers

Pundit Lab+ removes the need for external amplification when used with exponential transducers

Your Benefits
Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement

Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement

Automatic surface velocity calculation according to standards

Automatic surface velocity calculation according to standards

Same instrument can be used with pulse echo transducers

Same instrument can be used with pulse echo transducers

Your Benefits
B-Scan is constructed directly on the instrument as the scan is carried out

B-Scan is constructed directly on the instrument as the scan is carried out

Can be upgraded to Multi Channel

Can be upgraded to Multi Channel

Same instrument can be used with classic pulse velocity transducers

Same instrument can be used with classic pulse velocity transducers

Your Benefits
Full modular system allows to increase the number of channels by simply attaching additional probes

Full modular system allows to increase the number of channels by simply attaching additional probes

Unique real-time B-scan and panorama B-scan

Unique real-time B-scan and panorama B-scan

Same instrument can be used with classic pulse velocity transducers

Same instrument can be used with classic pulse velocity transducers

Your Benefits
Unmatched insights with unparalleled geometrical accuracy and image clarity at superior depths

Unmatched insights with unparalleled geometrical accuracy and image clarity at superior depths

Complete on-site structural assessment with A.I. support and various visualization modes (including AR)

Complete on-site structural assessment with A.I. support and various visualization modes (including AR)

Unbeatable on-site productivity thanks to superior ergonomics and digital workflows

Unbeatable on-site productivity thanks to superior ergonomics and digital workflows

Bandwidth
Bandwidth

20 to 500 kHz

Bandwidth

20 to 500 kHz

Bandwidth

20 to 500 kHz

Bandwidth

20 to 500 kHz

Bandwidth

20 - 70 kHz

Technology
Technology

Ultrasonic pulse velocity

Technology

Ultrasonic pulse velocity

Technology

Single channel ultrasonic pulse echo

Technology

Phased array ultrasonic pulse echo

Technology

Multi-channel Ultrasonic Pulse Echo

Measuring Resolution
Measuring Resolution

0.1 us

Measuring Resolution

0.1 us

Measuring Resolution

0.1 us

Measuring Resolution

0.1 us

Measuring Resolution
Pulse Voltage UPV
Pulse Voltage UPV

125 to 500 V

Pulse Voltage UPV

100 to 450 Vpp

Pulse Voltage UPV

Pulse Voltage UPV

Pulse Voltage UPV
Pulse Voltage UPE
Pulse Voltage UPE

Pulse Voltage UPE

Pulse Voltage UPE

± 50 to ± 200 V

Pulse Voltage UPE

+/- 150 V

Pulse Voltage UPE
Receiver Gain
Receiver Gain

1x, 10x, 100x, AUTO, Pundit Lab+ up to 1000x

Receiver Gain

1 to 10’000x (0 to 80 dB)

Receiver Gain

1 to 10’000x (0 to 80 dB)

Receiver Gain

1 to 10’000x (0 to 80 dB)

Receiver Gain
Nominal Transducer Frequency
Nominal Transducer Frequency

24 – 500 kHz

Nominal Transducer Frequency

24 – 500 kHz

Nominal Transducer Frequency

24 – 500 kHz

Nominal Transducer Frequency

50 kHz shear wave

Nominal Transducer Frequency

50 kHz

Pulse Shape
Pulse Shape

Square Wave

Pulse Shape

Square Wave

Pulse Shape

Square Wave

Pulse Shape

Square wave

Pulse Shape
Pulse Delay
Pulse Delay

Pulse Delay

Pulse Delay

Pulse Delay

8 ms – 200 ms

Pulse Delay
Number of Channels
Number of Channels

1

Number of Channels

1

Number of Channels

1

Number of Channels

8 (with upgrade option to 16)

Number of Channels

8 (with upgrade option to 16)

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Thickness measurement from tendon ducts beyond the rebar layer
Thickness measurement from tendon ducts beyond the rebar layer
Thickness measurement from tendon ducts beyond the rebar layer
Thickness measurement from tendon ducts beyond the rebar layer
Thickness measurement from tendon ducts beyond the rebar layer
Thickness measurement from tendon ducts beyond the rebar layer
Location of grouting defects in tendon ducts
Location of grouting defects in tendon ducts
Location of grouting defects in tendon ducts
Location of grouting defects in tendon ducts
Location of grouting defects in tendon ducts
Location of grouting defects in tendon ducts
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Pulse velocity determination
Quality assessment
Quality assessment
Quality assessment
Quality assessment
Quality assessment
Quality assessment
Compressive strength estimation
Compressive strength estimation
Pundit Lab+ only
Compressive strength estimation
Compressive strength estimation
Compressive strength estimation
Compressive strength estimation
SONREB
SONREB
Pundit Lab+ only
SONREB
SONREB
SONREB
SONREB
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Modulus of elasticity measurement
Curing status evaluation
Curing status evaluation
Curing status evaluation
Curing status evaluation
Curing status evaluation
Curing status evaluation
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Thickness measurement from a single side
Crack depth estimation
Crack depth estimation
Crack depth estimation
Crack depth estimation
Crack depth estimation
Crack depth estimation
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of delaminations, voids and honeycoming
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Location of hollow pipes
Location of pipes and tendon ducts beyond the rebar layer
Location of pipes and tendon ducts beyond the rebar layer
Location of pipes and tendon ducts beyond the rebar layer
Location of pipes and tendon ducts beyond the rebar layer
Location of pipes and tendon ducts beyond the rebar layer
Location of pipes and tendon ducts beyond the rebar layer
Assessment of fiber-reinforced concrete
Assessment of fiber-reinforced concrete
Assessment of fiber-reinforced concrete
Assessment of fiber-reinforced concrete
Assessment of fiber-reinforced concrete
Assessment of fiber-reinforced concrete
Additional Applications
Additional Applications

 

Additional Applications

 

Additional Applications

 

Additional Applications

 

 

 

Additional Applications

 

 

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Instrument Firmware
Instrument Firmware
  • Open interface
  • Integrated amplifier gain stage (Pundit Lab+ only)
  • Real time stamp (Pundit Lab+ only)
Instrument Firmware
  • Zoom and scroll for precise A-Scan inspection
  • On board storage and review of waveforms
  • Settings directly accessible on measuring screen
  • Dual cursor for manual A-Scan evaluation
  • Separate cursor to measure signal amplitude
  • Automatic and manual triggering and user adjustable trigger threshold
  • A-Scan update rate up to 25 Hz
Instrument Firmware
  • Gate function
  • Raw data export
  • Settings directly accessible on measuring screen
  • Advanced echo tracking technology helps identifying the main echo
  • Automatic estimation of the Pulse Velocity
Instrument Firmware
  • Raw data export
  • Settings directly accessible on measuring screen
Instrument Firmware
PC Software
PC Software

Pundit Link unlocks the full Pundit Lab+ capabilities

PC Software

PL-Link for analysis and export data to third party applications

PC Software

PL-Link for analysis and export data to third party applications

PC Software

PL-Link for analysis and export of data to third party applications

PC Software
Display
Display

79 x 21 mm passive matrix OLED

Display

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Display

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Display

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Display

Any compatible Apple® iPad (iOS 9.0 and higher)

Memory
Memory

> 500 measured values

Memory

Internal 8 GB flash memory

Memory

Internal 8 GB flash memory

Memory

Internal 8 GB flash memory

Memory

Up to 1 TB (depending on the Apple® iPad model)

Connections
Connections

USB connection to PC

Connections

USB host / device and Ethernet

Connections

USB host / device and Ethernet

Connections

USB host / device and Ethernet

Connections

Encrypted Wi-Fi connection to Apple® iOS tablet, USB port for Wi-Fi module

Report Generation
Report Generation
Report Generation
Report Generation
Report Generation
Report Generation

Cloud synchronization
Share via URL
Cloud-enabled logbook
Cloud-based raw data export
Cloud-based HTML export
Cloud-based report generation

Measurement Modes
Measurement Modes
  • Pulse velocity
  • Surface velocity
  • Data logging
  • E-modulus
  • Compressive strength correlation (Pundit Lab+ only)
  • Crack depth
Measurement Modes
  • Pulse velocity
  • Surface velocity
  • Data logging
  • E-modulus
  • Compressive strength correlation
  • Crack depth
  • Line Scan
  • Area Scan
Measurement Modes
  • Pulse velocity
  • Area Scan
  • A-Scan
  • B-Scan
  • Distance
Measurement Modes
  • Real time B-Scan
  • Panorama B-Scan
Measurement Modes

Line scan
Stripe Scan

Measuring Range
Measuring Range

Up to 15 m depending on concrete quality

Measuring Range

Up to 15 m depending on concrete quality

Measuring Range

Up to 1 m depending on concrete quality

Measuring Range

Ca. 1m depending on concrete quality

Measuring Range

Up to 3 m / 118 in depending on concrete quality

Transducers
Transducers
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Transducers
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Transducers
  • Dry-contact Pundit Pulse Echo transducer with control buttons, optical feedback, center marker and rulers for easy B-Scan measurements
  • Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
  • Connect third party transducers up to 500 kHz with BNC connector
Transducers

Dry-contact Pundit Array transducer with auxiliary LCD display and control buttons on handles

Transducers
Battery
Battery
Battery
Battery
Battery
Battery

Battery pack, 6x AA (NiMH), flight-safe

Special Features
Special Features
Special Features
Special Features
Special Features
Special Features

High definition focus view
Local focusing macro view
Wide panoramic B-scan
Augmented Reality
3D view
A.I.-assisted positioning
A.I.-assisted feature interpretation
A.I.-assisted material identification
Image stabilizer

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Standards
Standards
  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21
  • ГОСТ 17624
Standards
  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21
Standards
Standards
  • RI-ZFP-TU
Standards
Guidelines
Guidelines
Guidelines
Guidelines
  • RI-ZFP-TU
Guidelines
  • RI-ZFP-TU
  • FCC Part 15: 2010
  • Class A Digital Device
Guidelines
  • RI-ZFP-TU
  • FCC Part 15: 2010
  • Class A Digital Device
  • ZTV-ING Teil 5 Tunnelbau
  • ACI 228.2R-13
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Measurement Accessories
Measurement Accessories
  • 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
  • 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
  • Transducer 150 kHz (Two required for operation) (325 40 141)
Measurement Accessories
  • 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
  • 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
  • Pundit Pulse Echo Transducer, incl. cable, contact tester and documentation (327 40 130)
  • Upgrade Kit to Pundit 250 Array (327 30 130)
  • Battery complete (327 01 033)
  • Quick Charger (external) (327 01 053)
Measurement Accessories
  • Pundit® Dry-Point Shear Wave Transducer
  • Upgrade Kit to Pundit® 250 Array (327 30 130)
  • 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
  • 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
  • Battery complete (327 01 033)
  • Quick Charger (external) (327 01 053)
Measurement Accessories
  • Upgrade to 16 channel: Pundit Array Transducer (327 30 100), Pundit Array Transducer Extension Kit (376 30 377) and Dual Handle Kit (327 30 370)
  • Upgrade to dual handle: Dual Handle Kit (327 30 370)
  • Pundit Array Transducer Battery Pack Complete (327 30 337)
  • Rechargeable AA NiMH battery set of 6 (327 30 384S)
  • Calibrated tape set of 5 (327 01 071S)
  • Battery complete (327 01 033)
  • Quick Charger (external) (327 01 053)
Measurement Accessories

Upgrade your PD8000 with Ergonomic Package: Dual Handle Kit and mountable on the Pundit PD8000 iPad holder
Pundit PD8000 Transducer Battery Pack Complete
Rechargeable AA NiMH batttery set of 6
Calibrated tape set of 5

Software Upgrade Packages Available for existing units. Please contact your Proceq representative for more information.

Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Documents
Documents
Documents
Documents
Documents
Documents
Software
Software
Software
Software
Software
Software
Media
Media
Media
Media
Media
Media
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array
Pundit PD8000
Contact Proceq Call Form Mail Send Request